kpnl:biopac:scr
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
kpnl:biopac:scr [2015/10/27 08:18] – [Electrode Setup] admin | kpnl:biopac:scr [2016/09/01 19:43] (current) – [Useful links] admin | ||
---|---|---|---|
Line 1: | Line 1: | ||
+ | <WRAP center round todo 60%> | ||
+ | THIS PAGE IS UNDER CONSTRUCTION | ||
+ | </ | ||
+ | |||
+ | |||
+ | |||
====== Electrodermal Activity ====== | ====== Electrodermal Activity ====== | ||
+ | |||
+ | ====== Useful links ====== | ||
+ | * From a Biopac Webinar Series on EDA | ||
+ | * [[https:// | ||
+ | * [[https:// | ||
+ | * {{: | ||
+ | * {{: | ||
+ | * [[https:// | ||
+ | * {{: | ||
+ | |||
+ | * [[http:// | ||
+ | * [[http:// | ||
+ | (EDA) & Skin Conductance Responses (SCRs) | ||
+ | for Psychological Experiments ]] \\ | ||
+ | * [[http:// | ||
+ | * [[http:// | ||
+ | * [[http:// | ||
+ | * [[http:// | ||
+ | |||
+ | <note tip>Much of this information was gleaned from the following sources: | ||
+ | * Critchley, H.D. (2002). Electrodermal Responses: What Happens in the Brain. //The Neuroscientist, | ||
+ | * Boucsein, W., Fowles, D.C., Grimnes, S., Ben-Shakhar, | ||
+ | * Braithwaite, | ||
+ | </ | ||
+ | |||
There are several aspects of the EDA that one can measure: | There are several aspects of the EDA that one can measure: | ||
* **SC** = Skin conductance. Measured in microsiemens or micromhos (the reciprocal of resistance, ohm) | * **SC** = Skin conductance. Measured in microsiemens or micromhos (the reciprocal of resistance, ohm) | ||
Line 7: | Line 38: | ||
* **NS-SCR** = SCRs that occur without any identifiable eliciting stimulus | * **NS-SCR** = SCRs that occur without any identifiable eliciting stimulus | ||
* **ER-SCR** = SCR that is evoked by a specific eliciting stimulus | * **ER-SCR** = SCR that is evoked by a specific eliciting stimulus | ||
+ | |||
+ | The onset of an ER-SCR will occur 1 to 3 seconds after the event and will have a rise-time (i.e. from initial deflection to peak amplitude) of 0.5 to 5 seconds. | ||
+ | |||
+ | 10% of participants will be non-responders. | ||
Moreover, there are several ways to evaluate these responses. With regard to SCRs, one can | Moreover, there are several ways to evaluate these responses. With regard to SCRs, one can | ||
Line 18: | Line 53: | ||
- | ====== Useful links ====== | + | |
- | * [[http:// | + | |
- | * [[http:// | + | |
- | (EDA) & Skin Conductance Responses (SCRs) | + | |
- | for Psychological Experiments ]] \\ | + | |
- | * [[http:// | + | |
- | * [[http:// | + | |
- | * [[http:// | + | |
- | * [[http:// | + | |
===== Initial Setup ===== | ===== Initial Setup ===== | ||
Line 40: | Line 67: | ||
- Plug one lead into the '' | - Plug one lead into the '' | ||
{{: | {{: | ||
- | - Use electrode prep swab to clean the __index and middle__ fingers of the participant' | + | - Use electrode prep swab to clean the __index and middle__ fingers of the participant' |
- Remove two [[http:// | - Remove two [[http:// | ||
- Put extra [[http:// | - Put extra [[http:// | ||
- **You must use the specific SCR GEL101**. Other conductive gels (e.g. the EEG gel) are not appropriate. | - **You must use the specific SCR GEL101**. Other conductive gels (e.g. the EEG gel) are not appropriate. | ||
- | - Place them on the middle phalanx of the participant' | + | - Place them on the middle phalanx of the participant' |
- | {{ : | + | |
- Attach the pinch connector of one [[http:// | - Attach the pinch connector of one [[http:// | ||
+ | - Wait at least five minutes before recording. The electrolyte gel will continue to penetrate into the [[https:// |
kpnl/biopac/scr.1445951919.txt.gz · Last modified: 2015/10/27 08:18 by admin