kpnl:biopac:scr
This is an old revision of the document!
Table of Contents
Electrodermal Activity
There are several aspects of the EDA that one can measure:
* SC = Skin conductance. Measured in microsiemens or micromhos (the reciprocal of resistance, ohm) * SCL = tonic changes in SC * SCR = phasic changes in SC * NS-SCR = SCRs that occur without any identifiable eliciting sitmulus * ER-SCR = SCR that is evoked by a specific eliciting stimulus
Recording Electrodermal Responses
Useful links
Initial Setup
Electrode Setup
- Connect two LEAD110A leads into the EDA100C
- Plug one lead into the
Vin+
port and the other into theVin-
port
- Use electrode prep swab to clean the index and middle fingers of the participant's non-dominant hand
- Remove two EL507 electrodes.
- Put extra GEL101 on them
- Place them on the middle phalanx of the participant's index and middle fingers. Refer to the image below
- Attach the pinch connector of one LEAD110A to the EL507 electrode on the middle finger, and the other to the EL507 electrode on the pointer finger.
kpnl/biopac/scr.1445951291.txt.gz · Last modified: 2015/10/27 08:08 by admin